Training Safe Operation & Maintenance Circuit Breakers and Switchgear

 

DESCRIPTION

Switchgear (and circuit breakers) are obviously critical components in electrical distribution systems and their operation significantly affects the overall operation of the system. The workshop will discuss application, installation, maintenance and testing issues relating to medium and high voltage switchgear and circuit breakers. There will also be a coverage of low voltage switchgear. You will receive a thorough grounding in switchgear theory and standards. You will gain a solid understanding of the issues associated with the proper application, installation and maintenance of these critical items of equipment with an overriding emphasis on safety. This comprehensive and practical workshop emphasises medium voltage switchgear which represents most of the switchgear installed on electrical distribution systems. The focus here is on air blast, oil, SF6 and vacuum circuit breakers. Case studies covering the main manufacturer’s equipment will illustrate the important practical principles. Other power system protection components will be discussed as well to ensure that switchgear is understood in the correct context.

 

WORKSHOP OBJECTIVES

Delegates will learn about the following:

  • Selection of appropriate type and rating of circuit breakers and switchgear
  • Fundamentals of operation of switchgear
  • Switchgear components (CTs, VTs, relays, cable terminations)
  • Safe operational policies including safety rules and safety documents
  • Diagnostic tools and test equipment
  • Safe maintenance policies including safe working in switch rooms, indoor and outdoor substations

 

THE PROGRAM

 

SWITCHGEAR – ORIGINS & TYPES

  • Single line diagrams
  • Active and passive network components
  • Circuit breaker utilisation
  • Alternative forms of MV switchgear – ring main units, load breaking/fault making switches,
  • Fuse switches
  • HV fuses in combination with, and as alternative to circuit breakers
  • Auto-reclosers and auto-reclose operation

 

APPLICATION OF SWITCHGEAR

  • Principles of current interruption
  • Plain break circuit breakers
  • Bulk and small oil volume circuit breakers
  • Turbulator (explosion pot)
  • Operating mechanisms
  • Transfer earth circuit breakers
  • Air break and air blast switchgear
  • SF6 and Vacuum
  • Switchgear in association with disconnectors
  • Fixed and withdrawable designs
  • Switchgear standards
  • Factors affecting switchgear selection

 

SPECIFICATION OF SWITCHGEAR

  • Switchgear rating – highest system and impulse withstand voltages, load and short circuit currents
  • Simple and complex protection systems
  • Switchgear ancillaries, measurement CTs, VTs, relays
  • Cable terminations
  • Indoor and outdoor operation
  • Substation and switch room layouts and design

 

SHORT CIRCUIT TESTING

  • Symmetrical and asymmetrical breaking
  • Make and break operations
  • Understanding test oscillograms

 

CASE STUDY – SPECIFICATION FOR A 132 kV SWITCHBOARD

 

SAFETY POLICIES

  • General safety precautions and the use of personal protective equipment
  • Principles of safety rules
  • Principles of personnel authorisation
  • Operative training for safe operation of switchgear
  • Isolation in a circuit breaker context
  • Safety documentation
  • Operational and safety locking, caution and danger notices
  • Safe working in a substation environment
  • Safety interlocks
  • Substation alarms
  • Individual study task and presentation -safety policies in my company and how they might be improved

OPERATION OF MODERN SWITCHGEAR

  • Case Studies:

– Sprecher & Schuh

– Schneider

– ABB

– Siemens

ASSET MANAGEMENT IN A SWITCHGEAR CONTEXT

  • Principles of time and condition based asset management
  • Asset registers
  • Asset management systems

DIAGNOSTICS, TESTING & MAINTENANCE

  • Switchgear inspection methodologies
  • Partial discharge measurement and survey
  • Timing tests
  • Thermovision
  • Mechanisms of deterioration
  • Principles of circuit breaker maintenance
  • Maintaining oil circuit breakers
  • Contact maintenance and contact wipe
  • Oil testing
  • Maintaining vacuum circuit breakers
  • Maintaining SF6 circuit breakers
  • SOPs and DINs
  • Switchgear defects and defect control systems

Fasilitas Yang Diperoleh

  • Lokasi Training di Hotel Bintang 3-5
  • Ruang Pelatihan Full AC, Toilet dan Musholla
  • Perlengkapan Visual LCD Proyektor, & Whiteboard
  • Modul / Handout(Hard Copy & Soft Copy)
  • Training Kit (Co-Card, Bolpoin, & Buku Catatan)
  • 1x Makan Siang dan 2x Coffee Break (Snack)
  • Penjemputan Bandara Hotel (Pulang-Pergi selama pelatihan)
  • Basement Tempat Parkir Motor dan Mobil yang Aman
  • Akses Internet Wireless
  • Smoking Area.
  • Sertifikat Keikutsertaan Training
  • Merchandise menarik dari Duta Pro Training & Consulting
  • Konsultasi dengan Instruktur/Narasumber setelah Pelatihan

Biaya Training

  • Rp 6.800.000,- / Peserta (termasuk penginapan, minimal 2 peserta)

Lokasi Training di Yogyakarta

Keterangan

  1. Jumlah Peserta dapat memperngaruhi biaya training.
  2. Biaya dan Lokasi diatas hanya untuk Private Training dan Public Training, untuk In House Training penawarannya dapat menghubungi kami dilink berikut (kontak kami).
  3. Jumlah peserta, jadwal training dan lokasi training dapat menyesuaikan permintaan.
  4. Pemintaan lokasi yang diluar daftar diatas dapat menghubungi kontak Marketing Kami.

Dapatkan Penawaran Harga Training Terbaik dari Kami!.

Untuk melihat jadwal pelatihan ini kunjungi Jadwal Training Update dan jika ingin mendaftar pelatihan public atau online training ini, silakan isi form di Formulir Pendaftaran.

 

Spread the love